READ ME – for the IT department
This is a short and concise guide to issues you need to be aware of if your
hospital is in the process of purchasing or installing EDM2000. The note relates to the
technical areas of preparation before EDM200 in installed.
IT requirements:
- PC Client – running Windows NT, 2000 or XP linked to the network. The recommended
level is Windows XP, with a min. of 512Mb RAM.
- Access to a shared network drive with read and write access for all
dieticians and milk room staff. This requires a minimum of 250Mb of free
space to begin with but over several years this storage requirement might
increase to several Gb.
- If the file server is a Microsoft based server then
oplocks must be turned off! Unless this
step is taken then the server o/s will corrupt data. This is a well documented
Microsoft problem and sites may be charged to recover data lost due to an
incorrect setting.
- EDM2000 does not install any software or change any DLL's on the local
client PC.
- During installation it will normally be necessary for our Engineer to have administration
level access to the local PC's for configuration of the printers.
- The IT department is responsible for network backups to include the
\EDM2000 directory and all sub directories (data loss and recovery due to
inadequate backup/s will be a chargeable item).
- Remote access to the area of the server where EDM2000 is installed must be
provided. The preferred method is via VPN over broadband using either Terminal Server or Citrix. If this is not available, then a dial up link via PC Anywhere is
possible this but has not proven to be very stable in the past.
- We require an IT contact person that may become familiar with EDM2000 and act
as a primary link to the IT department should any issues arise.
- A standard user login for EDM2000 support staff to access only the \EDM2000
area for use by the site support engineer. (As a minimum the engineer account
should be power user and it is preferable to be at admin level.)
- Microsoft NT/2000 servers need to have 'auto disconnect' set to -1
or at least 720 (12 hours) - please see
Q138365 for full details.
If there are any questions or problems with the above details then this
matter can be clarified by contacting us directly. It
is recommended that this list is printed and checked with a copy signed and handed to
the EDM2000 engineer before installation is commenced.
The EDM2000 system, in its standard form, runs completely from a network
shared directory (normally called \EDM2000) and does not directly effect any other
application. It is a shared database application running a multi-user, multi
threading 32 bit software application used by the dieticians department. The
normal points of access to the program are from the dieticians PCs, milk room and
the wards.
|